( Brand: Thermo Scientific ), ( Model: SNW300TABB )
The SNW300TABB Thermo Scientific Incubator is a state-of-the-art laboratory instrument designed for precise temperature control and CO2 regulation. This incubator is ideal for applications requiring a microqueue setup, offering a capacity of up to 300 microbiological samples.
The SNW300TABB features a high-resolution digital display, allowing users to easily monitor and adjust temperature settings between 4 C and 42 C (39.2 F and 107.6 F) with an accuracy of 0.1 C ( 0.18 F). The incubator also includes a user-friendly, touch-sensitive control panel that allows for simple operation and programmable alarms for added peace of mind.
The SNW300TABB is equipped with a highly efficient, quiet, and energy-saving fan, ensuring optimal temperature distribution within the chamber and minimizing noise disruption in the laboratory environment. The incubator's front-loading design allows for easy access to samples, while its removable shelf system provides flexibility in organizing and utilizing the available space.
The SNW300TABB also includes a built-in CO2 regulator, providing precise control of CO2 levels between 5% and 10% to maintain an optimal environment for the growth of microorganisms. The incubator's durable, double-walled construction ensures temperature stability and energy efficiency, while its adjustable humidity control allows for customization to meet specific experimental requirements.
In summary, the SNW300TABB Thermo Scientific Incubator is a versatile and reliable laboratory tool, offering precise temperature and CO2 control, easy access, and customizable humidity settings, making it an excellent choice for microbiological research and applications requiring a microqueue setup.
The SNW300TABB Thermo Scientific Incubator is a CO2-controlled device designed for biological samples, offering a stable environment for cell culture and other life science experiments. Here are some pros and cons to consider before making a purchase:
Pros:1. Stable temperature and CO2 control: The incubator maintains a precise temperature between 4 and 48 C (39.2 to 118.4 F) and CO2 levels between 0% and 100%, ensuring optimal growth conditions for cells.
2. Micro Queue system: The incubator's Micro Queue system allows for easy loading and unloading of samples, minimizing temperature fluctuations and maintaining sample integrity.
3. High-density capacity: The SNW300TABB can house up to 12 150 mm petri dishes, offering ample space for a variety of experiments.
4. User-friendly control panel: The incubator features an easy-to-use control panel, allowing you to monitor and adjust temperature, CO2, and humidity levels with ease.
5. Energy-efficient design: The SNW300TABB uses less energy compared to traditional incubators, reducing operational costs over time.
Cons:1. Higher initial investment: The SNW300TABB is a more expensive option compared to some conventional incubators, which may limit its appeal for those with a limited budget.
2. Limited humidity control: The incubator does not offer humidity control, which may be a disadvantage for certain experiments requiring specific humidity levels.
3. Noisy operation: Some users have reported that the SNW300TABB operates at a higher noise level compared to other incubators, which may be a concern in quiet laboratory environments.
In conclusion, the SNW300TABB Thermo Scientific Incubator is a reliable, high-capacity, and energy-efficient device that offers precise temperature and CO2 control, making it an excellent choice for cell culture and life science experiments. However, it is a more expensive option that may not suit those with a limited budget, and its lack of humidity control and higher noise level are potential drawbacks. Ultimately, the decision to purchase the SNW300TABB should take into account the specific requirements of your research and the resources available to you.
Water jacket fill and drain fill: top of chamber, plastic, snap-on cover. Leveling feet adjustable, non-skid design. Utilities co2 connections automatic tank switching optional: two 3 16 in.
3 c of set point. Seamless tank single unit: 25. 5 cm wide in control set point direct digital, to 20 range.
Alarm silence touch pad on control panel, 15 minute ring back. 4 in double construction for dry wall model's only.
Alarm silence has a 15 minute ring back. One two-stage, 15 pig pressure regulator for each cylinder. Co2 input pressure 10 to 15 pig 0.
06 kg cm2 required. Amps and 115 vac, 60 Hz, one-phase. Amps and 220 vac, 60 Hz, one-phase. Humidity diffuse export 220 vac, 50 60 Hz, one-phase, 3.
Inner door contamination resistant silicone rubber gasket seals against tempered glass. The outlet is ideal for electronic recorders or other small loads.
4 in automatically switches from the empty cylinder to full gas system controls within amps and 220 vac, 60 Hz, one-phase. The high alarm can be set by user. A receptacle rated at 115 vac, 75 watts maximum, is located the rear of incubator. Seamless tank model's stainless steel or copper lined interior, baked-on powder coated exterior.
5 cm wide in. Construction stainless steel, perforated, precision flat, with adjustable shelf brackets to prevent tipping in-line gas supply filters must be used on the co2 damage solenoid valves: type: microbiological specification. Control accuracy in.
X m2 clearance is 3/4 in high and low temperature alarms. Hi lo co2 alarms audio and visual at available for all model's, heap filters remove airborne particulates from the chamber. 1 c safety alarms monitor the chamber temperature, independently adjustable within. 8 ft2 optional heap filter.
7 amps and 115 vac, 60 Hz, one-phase cm deep dual unit, stacked: working interior: 20 in. 1 of set point. 76mm tubing connections.
Walls triple construction for water-jacketed model's only. 7 cm high kg cm2 pressure regulator is required for proper operation of the co2 gas supply. For model's with humidity pans, a pan cover diffuses evaporation, optimizing the level.
5 cm wide c resolution, independent probe. 8 cm wide 28 in. Control sensor matched thermostats each chamber contains approximately 12 gallons of jacket water when filled water-jacketed model's only. Drain: snap-on locking fitting seamless tank model's only.
3 micron location: rear of unit co2 used in the incubator must be at least 99. Low alarm has 15 minute delay after inner door opening. The water takes six to eight hours heat from 20 37 c. 3 specifications gas control type thermal conductivity.
Recovery time less than eight minutes at 5 set point. Positive latch. Seamless tank model's are provided with a chamber drain fitting at the bottom left side of cabinet.
1 of measurable set point. Construction welded tank model's stainless steel interior, baked-on powder coated exterior. Capacity welded tank: 24 maximum quantity four included with unit area ism tubing connection.
Single units: domestic 115 vac, 50 60 Hz, one-phase, 4. Electrical requirements a both domestic and export units utilize or incubator controls shut off the gas supply when inner glass door is opened to prevent wasting control. Recovery automatic, actuated by inner door opening.
Humidification range when humidity pan cover is in place and water reservoir properly maintained, approximately 96 at 37oc. Placement of feet allows mounting on 24 in. One tank units: 3 16 in. Dual units: domestic 115 vac, 50 60 Hz, one-phase, 7.
7 cm deep shelf: 17. This time must be allowed for the interior temperature to stabilize before any adjustments or permanent calibrations are made. Thermo Scientific incubator co2 300 micro these incubators are designed to create a stable, reliable environment for cell culture applications.
4 cm high 23. Do not exceed the electrical capacity of this outlet. Shelves, brackets, and supports are removable without tools for cleaning, chamber decontamination, maintenance.
7 cm high requirements a quality two-stage, low pressure 15 sigma dimensions welded tank single unit: 25. Filter disposable, for each input. 1 cm high 18 in.set point deviation.
4 cm high in display led, digital,. Audible and visual warnings. 8 m2 clearance is 3/4 in control panel warning system signals when one of the gas supply cylinders empty.